HomeMy WebLinkAboutCC RESO 14,253RESOLUTION NO. 14,253
RESOLUTION TO AMEND, REVISE AND UPDATE THE
ELECTRICAL, MECHANICAL AND PLUMBING APPLI-
CATIONS INCLUDING THE RESPECTIVE FEES
WHEREAS, the City Council of the City of National City
hereby resolves that the Electrical, Mechanical and Plumbing
Permits do not contain all the items related to construction
and that such changes to fees are necessary to support the new
permit applications.
NOW, THEREFORE, BE IT RESOLVED that the City Council of
the City of National City hereby approves and adopts the new
Electrical, Mechanical and Plumbing Permit applications and
the respective enumerated fees as per the attached Exhibit
BE IT FURTHER RESOLVED that this Resolution shall be
effective July 1, 1984.
PASSED and ADOPTED this 21st day of February, 1984,
ATTEST:
CX'-4—
CITY CLE
"A".
NATION -al" CITY " DEPARTMENT OF BUILDINJ 'SAFETY
ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT
APPLICANT TO COMPLETE THIS PERMIT
NO.
ITEMS
APPLICANT TO COMPLETE THIS PERMIT
APPLICANT TO COMPLETE THIS PERMIT
N0,
ITEM
EACH
AMT.
N0.
ITEM
NO.
ITEM
NO.
ITEM
Switches
Receptacles
Light fixtures
First 10 items @ $ .50 each
Each additional $ .30
TOTAL OF ABOVE
Range/stove/oven
Dishwasher
Trash compactor
Fan outlets/hoods
Water heater
Wall/ceiling heaters
Sign fixture
TOTAL ABOVE @ $3.00 each
$3,00 each
NEW SERVICE PANELS/REPLACEMENT
To 100 amps
200 amps up
400 amps up
Over 400 amps $36.00 + $8.00/100 amps
$12.00 ea.
16.00 ea.
24.00 ea.
Temporary power pole -up to 200 amps 10.00 ea.
over 200 amps 15.00 ea.
Motors 1-15 h.p.
15-50 h.p.
50-100 h.p.
100-500 h.p.
500 up $40.00 + $10.00/100 h.p.
ELECTRICAL PERMIT
4.00
8.00
10.00
20.00
ea.
ea.
ea.
ea.
$ 5.00
TOTAL PERMIT FEE
4
x►-ittIT 'A"
For the installation or relocation of each forced
air or gravity type furnace/burner, including ducts
and vents attached to such appliance, up to and
including 100,000 B.t.u.'s.
For the installation or relocation of each forced
air or gravity type furnace/burner, including ducts
and vents attached to such appliance over 100,000
B.t.u.'s.
6.00
7.00
For the installation or relocation of each floor
furnace including vent.
For the installation or relocation of each
suspended heater, recessed wall heater or floor
mounted unit heater.
6.00
6.00
Bathtubs
Water closets
Dish washers
Shower stalls
Kitchen sinks
Acc. sinks
Lavatories
Washing machines
Urinals
Water heaters
"P" traps
floor sink/trap
TOTAL FOR ABOVE ITEMS @ $4.00 EACH
For the installation, relocation or replacement of
each appliance vent installed and not included in
an application.
For the repair of, alteration of, or addition to
each heating appliance, refrigeration unit, comfort
cooling unit, absorption unit, or evaporative cool-
ing system, including installation of controls
regulated by this Code.
For the installation or relocation of each boiler
or compressor 3 h.p. to 15 h.p. or each absorption
system 100,000 - 500,000 B.t.u.'s.
For the installation or relocation of each boiler
or compressor 15 h.p. - 30 h.p. or each absorption
system 500,000 - 1,000,000 B.t.u.'s.
For the installation or relocation of each boiler
or compressor 30-50 h.p. or each absorption system
1,000,000 - 1,750,000 B.t.u.'s
For the installation or relocation of each boiler
or compressor over 50 h.p. or each absorption
system over 1,750,000 B.t.u.'s.
For each air handling unit to and including 10,000
cubic feet per minute, including ducts attached
thereto.
3.00
6.00
10.00
15.00
20.00
30.00
5.00
For each air handling unit over 10,000 cubic feet
per minute.
8.00
For each evaporative cooler other than portable type.
For each ventilation fan connected to a single duct.
For each ventilation system which is not a portion
of any heating or air conditioning system author-
ized by a permit.
For the installation of each hood which is served by
mechanical exhaust, incl. the ducts for each hood.
For the installation or relocation of each domestic
type incinerator
5.00
3.00
5.00
5.00
8.00
Sand or grease trap
Gas pipe system 1-5 outlets
Each additional outlet
Water pipe system
Irrigation system - valves @
Sewer cap
Soil/vent pipe, alter/replace
Building drain, alter/replace
Sewer/septic tank, new/repair
Vacuum breaker/backflow device
Water softener
Swimming pool
Solar: Water heater
Pool heater
Other:
PLUMBING PERMIT
$ 4.00 ea. $
5.00 ea. $
1.00 ea. $
5.00 ea. $
4.00 ea. $
5.00 ea. $
5.00 ea. $
5.00 ea. $
7.00 ea. $
4.00 ea. $
7.00 ea. $
20.00 ea. $
15.00 ea. $
15.00 ea. $
$ 5.00
TOTAL PERMIT FEE
For the installation or relocation of each commer-
cial or industrial type incinerator
For each appliance or piece of equipment regulated
by this Code but not classed in other appliance
categories, or for which no other fee is listed in
this Code.
30.00
5.00
MECHANICAL PERMIT FEE
TOTAL PERMIT FEE
10,00
10.00
L.
PLUM E31 N&
—
PERMIT COMPUTATION
FOR APPLICANT TO FILL IN
NO.
ITEM INSTALLATION AND/OR RELOCATION
EACH
AMT.
2. 00
For issuing each permit $ 3 . 00
$ 3 . 00
For the Installation or relocation of each forced -air or
gravity type furnace or burner, including ducts and
vents attached to such appliance, up to and Including
100,000 B.t.u.'s.
6.00
-
UNIT FEE
In addition —
No.
For each plumbing fixture or trap or set of fixtures on
one trap
2.00
For the Installation•or relocation of each forced -air or
gravity typo furnace or burner, Including ducts and
vents attached to such appliance over 100,000 B.t.u.'s
7 50
AMPERES
For the Installation or relocation of each floor furnace,
including vent.
6.00
For each building sewer and each trailer
park sewer 5.00
For the Installation or relocation of each suspended
heater, recessed wall heater or floor mounted unit
heater.
6. 00
Rainwater systems - per drain 2.00
For the Installation, relocation or replacement of each
appliance vent Installed and not Included in an appli-
cation.
3.00
FEE SCHEDULE
For Issuing Each Permit $2.00
New Construction, for each Ampere of
Main Service, Switch, Fuse or Breaker .25
New Service on Existing Building, Increase 0-60 12.00
in Main Service, Switch, Fuse or Breaker 61-100 16.00
101-200 24.00 201-400 36.00
Over 400 amps 536.00 4- 58.00 per 100 amp or fractior. thereof
Remodel, Alterothon, No Change in Service,
for Each New Circuit Added 3.00
Temporary Service Up To and including 200 AMP 5.00
Temporary Service Over 200 AMP. per 100 AMP 10.00
Minimum Perm's Fee 5.00
'NOTE: AMPERE RATE SHALL APPLY TO THE SECONDARY
SIDE OF THE TRANSFORMER, OR TRANSFORMERS TOTAL
For each moved building plumbing system, inclu.
fixtures not relocated, replaced or alt. 5.50
For the repair of, alteration of, or addition to each
heating appliance, refrigeration unit, comfort cooling
unit, absorption unit, or evaporative cooling system,
Including Installation of controls regulated by this Code.
6. 00
For each water heater and/or vent 2.00
For each gas piping system of one (1) to
five (5) outlets 2.00
For the Installation or relocation of each boiler or
compressor to and Including three horsepower, or each
absorption system to end Including 100,000 B.t.u.'s.
6 .00
For each gas piping system of six (6) or
more, per outlet . 50
For the Installation or relocation of each boiler or
compressor over three horsepower to and including 15
horsepower, or each absorption system, over 100,000
B.t.u.'s to and Including 500,000 B.t.u.'s.
11
I .00
For each industrial waste, pre-treatment interceptor,
including its trap and vent, excepting kitchen type
grease interceptors functioning as fixture
traps 2 . 00 -
For the Installation or relocation of each boiler or
compressor over 15 horsepower to and including 30
horsepower, or each absorption system over 500,000
B.t.u.'s and including 1,000,000 B.t.u.'s.
15.00
For the Installation or relocation of each boiler or
compressor over 30 horsepower to and •Including 50
horsepower, or for each absorption system over
1,000,000 8.t.u,'s to and Including 1,750,000 B.t.u.'s.
22.50
For installation, alteration or repair of water piping
and/or water treatment equipment 2.00
For the Installation or relocation of each boiler or re -
frigeration compressor over 50 horsepower, or each
absorption system over 1,750,000 B.t.u.'s.
37.50
For repair or alteration or drainage or vent piping 2.00
For each lawn sprinkler system on any one meter
including backflow protection devices
therefor 2 . 00
For each air handling unit to and Including 10,000
cubic feet per minute, including ducts attached thereto.
4.50
For each air handling unit over 10,000 cubic feet per
minute.
50
For vacuum breakers or backflow protective devices
on tanks, vats, etc., or for installation on unpro-
tected plumbing fixtures including necessary water
i in — one(1)to five(5)any
piping g 2.00
For each evaporative cooler other than portable type.
4. 50
For each vent fan connected to a single duct.
3.00
For each ventilation system which Is not a portion of
heating or air conditioning system authorized by
a permit.
4.50
Over Five (5), each . 50
For the Installation of each hood which is served by
mechanical exhaust, Including the ducts for each hood.
4 , 50
Reinspection Fee 5.00
IP
For the installation or relocation of each domestic
type Incinerator.
7.50
Fee for failure to obtain permit 1 0.00
For the Installation or relocation of each commercial
or Industrial type Incinerator.
30. 00
Other
For each appliance or piece of equipment regulated by
this Code but not classed in other appliance categories,
or for which no other fee Is listed In this Code.
4.50
fv j�j 11-
`y p
TOTAL PERMIT
V •{Z "
IV\
Forgaspiping system of one (1) to
e (5)
2 . 00
,,,
Y
For refry eralwn fees - 1 horsepower = 1 ton
=1z.00�r3rus.
6.00
For the issuance of this permit.
1 0 . 00
1 0 . 00
f
C