Loading...
HomeMy WebLinkAboutCC RESO 14,381RESOLUTION NO. 14,381 RESOLUTION APPROVING PLANNED DEVELOPMENT PERMIT TO ALLOW A SHOPPING CENTER AT THE SOUTHEAST CORNER OF PLAZA BOULEVARD AND GROVE STREET The City Council of the City of National City, California, does hereby find, determine, order, and resolve as follows: WHEREAS, at a regular meeting of the Planning Commission of the City of National City, California, held on June 4, 1984, said Commission adopted Resolution No. 17-84 approving Planned Development Permit to allow development of a shopping center consisting of two fast-food drive-thru restaurants (4,400 square feet) and 26,600 square feet of retail and restaurant space on 2.76 acres at the southeast corner of Plaza Boulevard and Grove Street, subject to certain conditions of approval; and WHEREAS, testimony and evidence presented to the City Council at their July 10, 1984 meeting support the following findings: 1. The site for the proposed use is adequate in size and shape; 2. The site has sufficient access to streets; 3. The proposed use will not have an adverse effect upon adjacent or abutting properties; 4. The proposed use is deemed essential and desireable to the public convenience and welfare. NOW, THEREFORE, BE IT RESOLVED that this application is approved subject to the following conditions: 1. A cooperative agreement shall be executed between the City and the Grove Plaza developer providing for their payment of fifty (50) percent of the total cost of a traffic signal light at the intersection of Plaza Boulevard and Grove Street, and at 805 northbound off -ramps. Said traffic signal light shall be installed prior to final inspection and/or issuance of any certificate of occupancy. 2. Right turn only sign shall be provided for traffic exiting the shopping center onto Plaza Boulevard. 3. A grading plan, including on -site drainage structures shall be submitted concurrently with building plans for issuance of a building permit. 4. All cut slopes shall be 2:1 minimum unless evidence is supplied by a licensed soils consultant that a steeper slope is safe and stable. 5. Fourteenth Street adjacent to the project site shall be widened to 40 foot curb to curb and curb, gutter, sidewalk and paving installed. 6. Construct a 48" RCP in 14th Street to connect the existing pipes per City Engineer's drawing. 7. A 6" VCP is required to convey the sanitary sewer from 13th Street along the east boundary of the property line to 10" VCP flowing along 14th Street. Reconnect from old 10" main in property to the east to the 14th Street main. 8. A water system and fire hydrant shall be constructed in Grove Street per City Engineer's plan prior to final acceptance of the project. 9. For each restaurant, floor plans clearly indicating seating arrangement and statement regarding number of employees shall be submitted concurrently with building plans for issuance of a building permit. 10. A pedestrian walkway shall be provided between the public sidewalk on Plaza Boulevard and on Grove Street to each retail sales space and restaurant. 11. Parking facility shall be effectively screened from Plaza Boulevard and Grove Street. Mounded landscaping and/or combination decorative masonry wall and landscape required. 12. Parking spaces provided for the handicapped shall be in accordance with State regulations and be located adjacent to each building. In addition to pavement marking, an eye level, State approved symbol shall be mounted at the forward end of all such spaces. 13. No sign shall be permitted on the 14th Street frontage of this project. 14. Screen wall at property line on 14th Street shall not exceed a height of six (6) feet above official property line grade. 15. All trash enclosures visible from a public street shall be constructed of decorative masonry. 16. Landscaped slope adjacent to east property line of project site shall incorporate jute matting to minimize possibility of erosion. The developer shall enter into covenants and agreements required by the City to ensure permanent landscape maintenance. 17. Only two (2) pole -mounted or free standing signs shall be permitted. 18. Maximum height of any pole -mounted or free standing sign shall be fifty (50) feet to the top of the sign. 19. Roof signs shall be prohibited. 20. Exit doors on the south and east sides of the main building shall be subject to Department of Building and Safety approval. 21. Except as otherwise provided herein, development shall be in substantial compliance with the plans prepared by Brown/Leary, Architecture and Planning dated February 17, 1984, and identified as National City Planning Department Exhibit "A", Case File No. CUP-1984-4/PD-2-84. 22. Before this Planned Development Permit shall become effective, the applicant shall file a written statement with the Planning Department acknowledging and accepting all conditions imposed upon the approval of this permit. 23. Fireflow required is 4000 GPM for five hours at minimum PSI. ATTEST: 24. In order to provide this flow, provide the following: a) In addition to public hydrant at Plaza and Grove (southeast corner) provide additional on -site hydrant in parking lot. b) Dead end main on 14th Street shall be tied in. c) In lieu of #A and #B sprinkler entire complex (buildings C, D, and E). 25. In lieu of #24 provide area separation walls (2 hour minimum, every 8000 square feet, through roof) for buildings C, D, and E (fireflow will be 2500 GPM for 4 hours at 20 PSI). 26. Hours of operation of the fast-food, drive-thru restaurants shall be limited to no later than 11:00 p.m. on week nights and 12:00 midnight on Friday and Saturday with no deliveries prior to 7:00 a.m. PASSED and ADOPTED this 17th day of July, 1984. CITY CLERK