HomeMy WebLinkAboutCC RESO 10,554RESOLUTION NO. 10,.554
RESOLUTION GRANTING A RESIDENTIAL PLANNED DEVELOPMENT
PERMIT PURSUANT TO ORDINANCE 1077
(No. 39 - 910 Euclid Avenue)
The City Council of the City of National City,
California, does hereby find, determine, order and resolve
as follows:
1. At a regular meeting of the City. Planning Com-
mission on January 10, 1972, said Commission unanimously
adopted a recommendation that the owner of the real property
known as No. 39 - 910 Euclid Avenue, and more fully described
in Exhibit "A" attached hereto and made a part hereof as
though set forth in full, be granted a Residential Planned
Development Permit upon the conditions hereinafter stated:
2. That the City Council has received the recom-
mendation of the Planning Commission, and after full and
complete consideration of said recommendation hereby grants
a Residential Planned Development Permit to construct apart-
ment houses subject to the following terms and conditions:
A. That prior to the issuance of a building permit
by the Department of Building and Housing, the
property owner shall file with the Planning Depart-
ment an acknowledgment in writing stating that he
is cognizant of all conditions as hereinbelow set
forth and agrees to accomplish same prior to the
issuance of a certificate of occupancy by the
Housing Department, City. of National City.
B. Site development shall be in accordance with a
site development plan approved by the Planning
Commission.
C. Maximum ratio of fill slopes shall be 2 to 1.
(3 to 1 preferable)
1) All slopes shall be planted and provided with
a permanent underground sprinkler system.
2) Maximum ratio of slope for grass banks shall
be 4 to 1.
D. Area allocated as useable open space (excluding
pool area) shall be surfaced with grass and provided
with a permanent underground sprinkler system.
1) Pool area shall be completely enclosed within
a six foot (6.') high fence; deck area shall be
surfaced with 4-inch thick concrete.
2)Children's play areas shall be enclosed by a
six foot (6') high fence and surfaced with grass
or six inches (6") of sand. Play apparatus
shall be provided.
E. Off-street parking areas and areas surfaced for
vehicular access, except driveway approach on Euclid
Avenue and approaching drive, shall be surfaced with
minimum two inch (2".) thick asphalt surfacing over
two inch (2") base of compacted material as specified
by the City Engineer. All such paving shall there-
after be properly maintained.
1) All parking sites shall be striped for a
minimum width of nine feet (9').
2) All parking sites shall be sloped to drain
with a maximum grade of 2%..
3) Parking sites shall be installed and maintained
at a ratio of 1.5 spaces per two -bedroom units and
1.3 spaces per one -bedroom units.
F. Concrete walkways (a minimum width of 36 inches)
shall be installed in front of all parking spaces to
protect the landscape from foot traffic.
1) Concretewheel stops at all parking sites are
required if concrete walkway is less than five
feet (5') in width.
G. Excluding area of ingress and egress, the required
ten foot (10'.) setback on Euclid Avenue shall be land-
scaped and provided with a permanent underground
sprinkler system.
1) Said landscaping shall be permanently main-
tained in a growing and healthy condition.
2) Two (2) trees, 15-gallon minimum size, shall
beplanted within said setback area, but no
closer than five feet (5') from edge of sidewalk.
H. Pedestrian walkways providing access to dwelling
units, parking areas, and service areas shall be a
minimum width of 48 inches, except as otherwise
provided herein.
I. Enclosed trash areas shall be provided at a minimum
of three (3) locations, each adequate in size to house
two rubbish dumpsters. (Six dumpsters required for
entire project).
J. All yards and open space that is not otherwise
used for walkways, driveways, or useable open space
shall be landscaped and provided with a permanent
underground sprinkler system.
K. All vehicular access areas, parking areas, and
pedestrian walkways that provide access to dwelling
units shall be lighted.
1) All exterior lighting, except shadow lighting,
shall be installed on decorative poles and serviced
by underground wires.
2) All lighting shall be so shaded and adjusted
to fall only upon those properties on which said
light source is located.
L. Laundry and dryer facilities shall include:
1) Minimum of ten (10). washers and five (5) com-
mercial dryers.
2). Adequate deep sink and foldingtable facilities.
M. Building number 1 shall be relocated to maintain
a minimum distance of fifteen feet (15') from easterly
property line (13 feet shown).
N. Building number 2.shall be relocated to maintain
a minimum distance of fifteen feet (15') from easterly
property line (13 feet shown).
0. Parking areas tobe used only for parking of
vehicles used by tenants and their guests. No auto-
mobile repair, etc., shall be allowed. No commercial
uses shall be allowed. No storage of boats, campers,
or other equipment in required yard areas.
P. One architecturally designed identification/
directional sign may be located on the site, provided,
however, said sign shall not exceed 32 square feet
and be located closer than 10 feet from any property
line.
Q. At the intersection of Euclid Avenue and the pro-
posed private drive, the following shall be installed,
constructed and/or accomplished in accordance with
City of National City engineering specifications:
1) Installation of concrete cross gutter per Std.
Dwg. 31-SB.
2) Installation of City standard stop sign with
painted street bar.
3) Paint curb red, no parking.
R. Type "CS" guard fence assembly shall be installed
at the easterly end of llth Street. Location and
installation shall be in accordance with. City Engineer's
specifications.
S. Median provided in approach drive shall be land-
scaped and provided with a permanent underground
sprinkler system.
T. Proposed swale in driveways shall be installed
in accordance with. National City Std. Dwg. 9-SB.
U. Curb and gutter combinations in driveways shall
be type "G"..
V. A minimum of four (4) private hydrants shall be
installed as recommended by the Fire Marshal.
W. This permit shall expire one year after the date
ATTEST:
of approval by the City Council unless the project
is completed in compliance herewith Within that time.
PASSED AND ADOPTED this 25th day of January, 1972.